Stöbich Fire and Smoke Curtain S

Product Description

The base area of the closure can be either rectangular or polygonal with angles between 30°* and 179°*. Despite the formation of corners, no additional support elements are required. In addition to a closed polygonal shape, open systems can also be implemented, which are attached to the wall structure with special guide rails. With the help of the standard “Gravigen” drive system, the fire curtain can be closed without external energy.

With Fibershield®-S, challenging partitioning geometries can be realized while simultaneously meeting the requirements for room closure for over 90 minutes.

Function

Textile fire protection curtain

Executable protection target

EW 90

Fabric

Fire & Smoke Fabric E | Stoebich Fire & Smoke Fabric H

Proof

IBS 08062416 | UL 10D | UL 10 (b) (2009) | UL 10 (c) (2009) | UL 10 (d) (2009) | NFPA 252 (2012)

Closing direction

From top to bottom

Fire resistance

2 hours fire rating according to UL 10D, 20 minutes fire rating according to UL 10B, UL 10C, NFPA 252

Closing cycles

C1 number of closing cycles 500

* Angle specifications: Complete range min. 30° to max. 179°

Angle specifications (standard):

The minimum standard angle is 65°, the maximum standard angle is 165°. These specifications refer to external angles and internal angles with Ecotex 1100 A2 and Heliotex 9 fabrics.

Angle specifications (special):

The maximum special angle can be up to 179° (only with Ecotex 1100 A2).

Restriction for angles below 65°:

1) Angles below 65° must be broken down into a 90° angle and an obtuse angle. The standard construction can be used here.
2) Notwithstanding point 1, a special construction must be requested.

Legend system components:
1 = Smoke detector
2 = Casing
3 = Side guids
4 = Tubular motor
5 = Fabric
6 = Closing element
7 = Coil
8 = Control module
9 = Control with operating unit
10 = Manual release
SL = System length

Dimensions and system structure
The combination of classifications or the ratio of clear system width to clear system height may reduce the maximum dimensions specified, and the dimensions of the housing and guide rails may vary. The information provided in the offer applies.

Fabric

System width

Drop length (AL)

t (mm)

h (mm)

Fabric

Ecotex 1100 A2

System width

‹ 50 m

Drop length (AL)

‹ 3 m

t (mm)

490

h (mm)

125

Fabric

Ecotex 1100 A2

System width

‹ 50 m

Drop length (AL)

› 3 m - ≤ 6 m

t (mm)

490

h (mm)

225

Fabric

Heliotex 9 EW 90

System width

‹ 50 m

Drop length (AL)

≤ 2,2 m

t (mm)

490

h (mm)

125

Fabric

Heliotex 9 EW 90

System width

‹ 50 m

Drop length (AL)

› 2,2 m - ≤ 4,5 m

t (mm)

490

h (mm)

225

Fabric

Heliotex 9 EW 90

System width

‹ 50 m

Drop length (AL)

› 4,5 m - ≤ 6 m

t (mm)

490

h (mm)

450

The installation situation must comply with the building regulations of the country of installation. The fire resistance of a ceiling or wall support structure and the adjacent components must be at least equal to that of the fire and/or smoke protection barrier/fire and/or smoke protection curtain. The stability and serviceability of the adjacent walls and components must be verified under normal environmental conditions and in the event of a fire. See also notes on standard supporting structures in EN1366-7:2004 and EN1363-1:2020. Even in the event of a fire, the fire protection system must not be exposed to any additional load other than its own weight.

Deviations from standard dimensions available on request.

Bottom Bar

Standard

Casing Standard

Casing (open)
h = from table | t = 490 mm | d = 290 mm

Casing (closed)
h = from table | t = 490 mm | d = 290 mm

Side Guides

Guide for open polygons
a = 117 mm | b = 278 mm

Make an Inquiry

Protect your building with intelligent fire and smoke protection solutions engineered for performance, reliability, and architectural flexibility. Whether you’re planning a new project, upgrading an existing facility, or exploring specialized safety systems, Stöbich delivers advanced protection tailored to your exact requirements. Make an inquiry today and discover how our innovative fire protection technologies can help safeguard people, property, and operations with confidence.

Name(Required)
Email(Required)

About Our Fire CUrtain S

Fire Curtain S is Stöbich’s advanced textile fire protection system designed for complex building geometries and unconventional architectural layouts. Engineered to accommodate both rectangular and polygonal openings, the system provides exceptional design flexibility while delivering reliable fire compartmentation, concealed integration, and gravity-driven emergency deployment.

Designed for Complex Architectural Layouts

Modern buildings often feature:

  • Irregular floor plans
  • Angled walls
  • Curved layouts
  • Open atriums
  • Non-traditional compartment boundaries

These architectural elements can create significant fire protection challenges that traditional fire barriers may struggle to address.

Fire Curtain S was developed specifically to provide effective fire compartmentation within complex and unconventional building environments.

Flexible Geometry for Unique Designs

Unlike conventional fire barriers that are typically limited to simple rectangular openings, Fire Curtain S can accommodate:

  • Rectangular configurations
  • Polygonal base areas
  • Angles between 30° and 179°
  • Irregular compartment shapes
  • Customized architectural layouts

This flexibility allows the system to adapt seamlessly to demanding design concepts without compromising fire protection performance.

Corner Formation Without Additional Supports

One of the most innovative features of Fire Curtain S is its ability to create corners and complex shapes without requiring additional support elements.

Benefits include:

  • Simplified installation
  • Reduced structural complexity
  • Cleaner architectural lines
  • Less visual intrusion
  • Greater design freedom

By eliminating bulky corner supports and rigid framing systems, the curtain maintains a more refined and integrated appearance.

Open and Enclosed Configuration Options

Fire Curtain S can be configured in multiple ways to accommodate project requirements.

The system supports:

  • Fully enclosed polygonal designs
  • Open configurations
  • Wall-mounted applications
  • Specialized guide rail installations

This versatility significantly expands the range of potential applications and compartmentation strategies available to architects and engineers.

Ideal for Architecturally Demanding Projects

The adaptability of Fire Curtain S makes it suitable for a wide range of challenging environments, including:

  • Atriums
  • Transportation terminals
  • Shopping centers
  • Public buildings
  • Industrial facilities
  • Commercial developments
  • Mixed-use projects

Its ability to protect unconventional spaces allows designers to achieve ambitious architectural goals without sacrificing fire safety.

Reliable Gravigen Deployment Technology

Fire Curtain S utilizes Stöbich’s proven Gravigen technology for dependable emergency operation.

The gravity-driven system allows the curtain to deploy automatically without requiring external power during emergency situations.

Advantages include:

  • Fail-safe operation
  • Automatic deployment
  • Reliable performance during power outages
  • Reduced system complexity
  • Long-term operational confidence

This proven technology helps ensure dependable closure when protection is needed most.

Advanced Fire Resistance Performance

Fire Curtain S incorporates Fibershield®-S technology to provide exceptional fire protection performance.

The system can achieve:

  • Room-closing fire protection
  • Fire resistance exceeding 90 minutes
  • Reliable compartmentation performance
  • Protection against flame and heat spread

These capabilities help support critical life safety objectives by maintaining separation between building compartments during fire events.

Concealed Protection for Modern Architecture

Fire Curtain S is designed to integrate discreetly into contemporary building environments.

Its concealed installation options help preserve:

  • Open visual concepts
  • Architectural aesthetics
  • Clean sightlines
  • Spatial continuity
  • Design intent

The curtain remains largely invisible during normal operation and deploys only when required, allowing fire protection to function without impacting the overall appearance of the space.

Why Choose Fire Curtain S?

Fire Curtain S combines:

  • Polygonal fire curtain technology
  • Corner-forming capability without support structures
  • Flexible geometry accommodation
  • Fibershield®-S fire resistance
  • Gravigen fail-safe deployment
  • Concealed architectural integration

Together, these features create a highly adaptable fire protection solution that enables architects and engineers to overcome complex compartmentation challenges while preserving the openness and creativity of modern building design.