Stöbich Fire Multi Detector

Product Description

The core of the solution for prevention – especially of large fires – is the reduction of the time between and fire detection by using optical-thermal detectors in combination with the patented detection software.

This makes it possible to detect smoke, temperatures and natural flames with just one detector. Interference variables such as clouds, sun, fog, dust or heat-emitting vehicles do not lead to false alarms. This makes this solution is excellently suited for indoor and outdoor use, especially for large monitoring areas.

The 24/7 availability ensures a high level of security in conjunction with intelligent information processing and ensures that all necessary agencies are immediately informed, alerted and provided with important additional information.

With this solution, large fires with all their drastic consequences for people, operations and the environment are a thing of the past.

Main features

Monitoring of indoor, outdoor and dynamic areas (conveyor belts)

Daily and time-dependent detection parameters possible

Colour and intensity-based flame and smoke detection analyses result in a high detection rate and minimised false alarms.

Secure transmission of alarms with live still image into the SMC app enables visual review of incidents and improved situational awareness.

The Fire Multi Detector has a built-in thermopile module that analyses temperatures in the detection area.

Neutralisation of the occurring harmful gases

Internal recording enables the verification and analysis of events

Product features

Technical data

Dimensions L x B x H

373 x 263 x 100 mm

Operating voltage

312–24 V DC (PoE possible)

Power

4,5 W

Protection class

IP66

Operating temperature

Operation: -20 °C bis 50 °C
Storage: -10 °C bis 70 °C

Humidity during operation

20 % to 80 % relative humidity (non-condensing)

Weight

3,0 kg

Approvals

CE marking, complies with Part 15 of the FCC CFR47, RoHS compliant

Distance

up to 30 m

up to 80 m

Detection range optical

H: 85° · V: 63°

H: 34° · V: 25°

Detection range thermal

H: 90°

H: 39°

Resolution thermal

H: 82 px · V: 62 px

Temperature range

-30 °C to 300 °C

Monitoring area

30 cm Fire: 70 m²
60 cm Fire: 290 m²

30 cm Fire: 450 m²
60 cm Fire: 1.850 m²

Detection

Flame, smoke and temperature detection

Image sensor

1/4 inch CMOS with progressive scan

Automatic gain control AGC

Automatic and manual

WDR image enhancement

greater-than 80 dB

Signal-to-noise ratio

greater-than 50 dB

Minimum lighting

20 lx (lux) IR floodlight, required for smoke detec-tion. Fire detection and temperature monitoring are fully functional in complete darkness.

Storage capacity

Integrated recording on internal SD card (up to 64 GB)

Available archiving formats

JPEG und MPEG-4

Alarms and relays

4 potential-free relay outputs Relay 1-3: 600 mA at 60 V DC Relay 4: 2.2 A at 60 V DC

Options

Central visualisation of detector images

Advanced contamination protection

Targeted deletion

Connection to existing fire protection systems

Make an Inquiry

Protect your building with intelligent fire and smoke protection solutions engineered for performance, reliability, and architectural flexibility. Whether you’re planning a new project, upgrading an existing facility, or exploring specialized safety systems, Stöbich delivers advanced protection tailored to your exact requirements. Make an inquiry today and discover how our innovative fire protection technologies can help safeguard people, property, and operations with confidence.

Name(Required)
Email(Required)

About Our Fire Multi-Detector

The Fire Multi-Detector is Stöbich’s advanced fire prevention and detection system designed to identify developing fire hazards quickly, accurately, and reliably. By combining optical and thermal sensing technologies with patented detection software, the system provides early fire recognition, minimizes false alarms, and supports faster emergency response across large indoor and outdoor monitoring environments.

Early Fire Detection Saves Time and Lives

One of the most critical factors in fire protection is how quickly a fire can be detected.

The Fire Multi-Detector is engineered to reduce the time between fire ignition and fire detection, helping facilities:

  • Protect occupants
  • Activate suppression systems sooner
  • Reduce property damage
  • Minimize operational disruption
  • Support faster emergency response

Early intervention can significantly reduce the impact of a fire event before it escalates into a larger emergency.

    Multiple Detection Technologies in One System

    Unlike conventional systems that often rely on a single sensing method, the Fire Multi-Detector combines multiple detection principles within a single device.

    Using advanced optical and thermal technologies, the system can identify:

    • Smoke development
    • Elevated temperatures
    • Visible flames

    This multi-layered approach provides a more comprehensive and dependable method of fire detection.

    Intelligent Fire Recognition

    At the heart of the Fire Multi-Detector is patented detection software designed to analyze environmental conditions and identify genuine fire hazards.

    By combining data from multiple sensing technologies, the system can recognize developing fire conditions at an exceptionally early stage while maintaining a high level of accuracy.

    This intelligent approach improves both detection speed and reliability across a wide range of operating environments.

    Reducing False Alarms

    False alarms can disrupt operations, increase costs, and reduce confidence in fire protection systems.

    The Fire Multi-Detector is specifically engineered to distinguish actual fire events from common environmental interference factors, including:

    • Sunlight
    • Fog
    • Clouds
    • Dust
    • Vehicle heat emissions
    • Changing weather conditions

    By filtering out these variables, the system dramatically reduces nuisance alarms while maintaining highly sensitive fire detection performance.

    Ideal for Indoor and Outdoor Applications

    The system’s advanced detection capabilities and resistance to environmental interference make it suitable for a wide range of monitoring environments.

    Common applications include:

    • Industrial facilities
    • Logistics centers
    • Recycling operations
    • Airports
    • Transportation terminals
    • Energy infrastructure
    • Manufacturing plants
    • Storage yards
    • Large public spaces

    Its ability to monitor expansive areas efficiently makes it especially valuable where traditional point detection systems may provide limited coverage.

    Continuous 24/7 Monitoring

    The Fire Multi-Detector provides uninterrupted protection around the clock.

    Benefits of continuous monitoring include:

    • Constant situational awareness
    • Immediate hazard recognition
    • Consistent facility protection
    • Enhanced operational security
    • Reliable performance regardless of operating schedules

    This permanent readiness helps ensure that emerging fire risks can be identified at any time.

      Faster Emergency Communication

      Detection is only the first step in an effective fire protection strategy.

      Once a fire event is identified, the Fire Multi-Detector supports rapid communication by helping notify responsible personnel and emergency responders immediately.

      This allows teams to receive critical information regarding:

      • Incident location
      • Fire conditions
      • Potential hazards
      • Response priorities

      Faster communication supports quicker decision-making and more coordinated emergency response efforts.

      Focused on Prevention, Not Just Detection

      The Fire Multi-Detector is designed with a proactive approach to fire safety.

      By combining:

      • Early hazard recognition
      • Intelligent data analysis
      • False alarm reduction
      • Continuous monitoring
      • Rapid notification capabilities

      the system helps reduce the likelihood of small incidents developing into major fire events that can cause significant damage, downtime, and safety risks.

      Why Choose the Fire Multi-Detector?

      The Fire Multi-Detector combines:

      • Optical smoke detection
      • Thermal monitoring
      • Flame recognition capabilities
      • Patented detection software
      • False alarm resistance
      • 24/7 monitoring
      • Rapid emergency communication

      Together, these technologies create an intelligent fire prevention solution that helps facilities identify hazards earlier, respond faster, and improve overall fire safety performance across complex environments.