Stöbich Smoke Curtain P

Product Description

Stoebich Smoke Curtain P stands out thanks to its flexibility when implementing made-to-measure solutions. The smoke curtains are made of one piece of material that is up to 1968.5″ in width and an unrolled length of 374″, and is designed for high time classes at temperature loads up to 1,112°F (D) and 2,020°F (standard temperature curve – DH). When using guide rails, 0% leaks can be realized across the entire smoke curtain. The curtain is closed without any external energy with a “Gravigen” drive motor. Stoebich Smoke Curtain P is also suitable as a floor-closing and space-creating smoke curtain, and can be equipped with an opening to allow persons to pass. Also, the clever construction allows it to be combined with the passable smoke curtain.

Construction Type

Textile smoke curtain

Fabric

Stoebich Fire & Smoke Fabric P 600.1 A2 | Fire & Smoke Fabric P

*

Closing Direction

From top to bottom

Closing cycles

1,000 cycles according to DIN EN 12101-1

n

Classification

D 60 | Classification according to DIN EN 12101-1

Triggering

Approved hold-open system | To be provided on site

Constructive system design (with guide rail)

Fabric

System width (SB)

Drop length (AL)

t (mm)

h (mm)

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 0,8 m - ≤ 1,6 m

Drop length (AL)

≤ 3,5 m

t (mm)

190

h (mm)

250

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 1,6 m - ≤ 30 m

Drop length (AL)

≤ 3,5 m

t (mm)

190

h (mm)

200

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 1,2 m - ≤ 30 m

Drop length (AL)

”>

t (mm)

190

h (mm)

250

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 2,0 m - ≤ 20 m

Drop length (AL)

”>

t (mm)

235

h (mm)

290

Constructive system design (without guide rail)

Legend System components:
1 = Fastening module
2 = Fabric
3 = Finishing strip
4 = Penetration collar

Fabric

System width (SB)

Drop length (AL)

t (mm)

h (mm)

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 0,8 m - ≤ 1,6 m

Drop length (AL)

≤ 3,5 m

t (mm)

190

h (mm)

250

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 1,6 m - ≤ 50 m

Drop length (AL)

≤ 3,5 m

t (mm)

190

h (mm)

200

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 1,2 m - ≤ 50 m

Drop length (AL)

”>

t (mm)

190

h (mm)

250

Fabric

Protex 600.1 A2 / 1100.1 A2

System width (SB)

≥ 2,0 m - ≤ 50 m

Drop length (AL)

”>

t (mm)

235

h (mm)

290

Bottom Bar

Standard
Typ 4,6

Spring-loaded closing strip
Typ = 4,6 F (Special)

Spring-loaded closing strip
Typ = 3,84 F (Special)

Alternatives for installation

Installation to the wall

Installation to the ceiling

Installation over suspension

Side Guides

Type 105 E (niche)
a = 105 mm
b = 74 mm

AL = ≤ 6 m
A = ≤ 50 m²

Type 105 E (Wall)
a = 105 mm
b = 74 mm

AL = ≤ 6 m
A = ≤ 50 m²

Type 160 E
a = 160 mm
b = 100 mm

AL = ≤ 9 m
A = ≤ 120 m²

Type 105 E (embrasure)
a = 105 mm
b = 74 mm

AL = ≤ 6 m
A = ≤ 50 m²

Type 80 E
a = 80 mm
b = 74 mm

AL = ≤ 3,5 m
A = ≤ 18 m²

Make an Inquiry

Protect your building with intelligent fire and smoke protection solutions engineered for performance, reliability, and architectural flexibility. Whether you’re planning a new project, upgrading an existing facility, or exploring specialized safety systems, Stöbich delivers advanced protection tailored to your exact requirements. Make an inquiry today and discover how our innovative fire protection technologies can help safeguard people, property, and operations with confidence.

Name(Required)
Email(Required)

About Our Smoke Curtain P

Smoke Curtain P is Stöbich’s premium made-to-measure smoke containment system designed for large open spaces, complex architectural environments, and demanding life-safety applications. Combining exceptional dimensional capabilities, advanced smoke control performance, and discreet architectural integration, the system helps protect occupants while preserving the open aesthetics of modern buildings.

Designed for Large Open Spaces

Smoke Curtain P is engineered for projects where traditional smoke barriers may not provide adequate coverage.

The system can be manufactured from a single continuous piece of material up to:

  • 1968.5 inches wide
  • 374 inches unrolled length

This large-scale capability makes it ideal for:

  • Atriums
  • Shopping centers
  • Airports
  • Transportation terminals
  • Commercial buildings
  • Public gathering spaces

By protecting expansive openings with a single curtain system, architects can maintain visual openness while meeting smoke control requirements.

Advanced Smoke Containment Performance

Effective smoke control is critical during the early stages of a fire.

When paired with guide rails, Smoke Curtain P can achieve extremely low smoke leakage, helping to:

  • Restrict smoke migration
  • Maintain visibility
  • Protect evacuation routes
  • Improve compartmentation
  • Support emergency response efforts

This high-performance containment helps create safer conditions for occupants and first responders.

High-Temperature Resistance

Smoke Curtain P is engineered to maintain operational integrity under demanding fire conditions.

The system is capable of withstanding:

  • Temperatures up to 1,112°F in Class D applications
  • Temperatures up to 2,020°F under DH classification

These performance capabilities help ensure reliable smoke containment during critical phases of a fire event.

Reliable Gravigen Technology

Smoke Curtain P utilizes Stöbich’s proven Gravigen drive technology.

Unlike systems that rely solely on powered deployment, Gravigen allows the curtain to close automatically using gravity.

Benefits include:

  • Automatic emergency deployment
  • Dependable operation during power loss
  • Reduced system complexity
  • Enhanced reliability
  • Long-term operational confidence

This fail-safe design helps ensure the curtain deploys when protection is needed most.

Flexible Application Options

Smoke Curtain P is designed to support a variety of smoke control strategies.

Available configurations include:

  • Floor-closing smoke curtains
  • Space-dividing smoke barriers
  • Pass-through smoke protection systems
  • Integrated opening solutions
  • Combined smoke compartmentation systems

This flexibility allows architects and engineers to tailor smoke protection to the specific needs of each project.


 

Passable Smoke Protection Solutions

For high-traffic environments and escape routes, Smoke Curtain P can be configured with integrated pass-through openings.

These specialized designs help:

  • Maintain occupant movement
  • Support evacuation routes
  • Improve accessibility
  • Accommodate high pedestrian traffic
  • Enhance operational functionality

The system can also be combined with passable smoke curtain technologies for even greater design flexibility.

Concealed Architectural Integration

Smoke Curtain P is designed to remain virtually invisible until deployment.

Its housings and guide rails can be integrated discreetly into:

  • Ceilings
  • Structural elements
  • Architectural finishes
  • Open-plan environments

This concealed approach preserves:

  • Clean sightlines
  • Modern aesthetics
  • Open architectural concepts
  • Interior design integrity

The result is effective smoke protection without visual compromise.


 

Why Choose Smoke Curtain P?

Smoke Curtain P combines:

  • Large one-piece curtain dimensions
  • Advanced smoke containment performance
  • Extremely low leakage capabilities
  • High-temperature resistance
  • Gravigen gravity-driven deployment
  • Flexible configuration options
  • Concealed architectural integration

Together, these features create a sophisticated smoke control solution that helps modern buildings achieve both exceptional life-safety performance and architectural excellence.